HomeNetworkingError exiting config-vlan mode 47: NV storage failure

Error exiting config-vlan mode 47: NV storage failure


Whereas working a Cisco catalyst Change like 2960s, 3550s and many others. particularly throughout configuring VLANs, an “NV Storage failure” error is typically reported by some directors. The exact error code displayed is – Error exiting config-vlan mode 47: NV storage failure”.

In truth,  many instances such errors have been seen in Community simulators like GSN3 ,Dynamips or not too long ago EVE-NG.


Instance Situation: Error exiting config-vlan mode 47: NV storage failure”

Right here is the situation (whereas configuring VLAN) which led to the error show –

Change(config-vlan)#vlan 20

%Error exiting config-vlan mode 47: NV storage failure

On this error is obtained,

 

Step 1 :

Delete VLAN.dat file

delete flash:vlan.dat

Delete filename [vlan.dat]?

Delete flash:vlan.dat? [confirm]

 

Step 2 :

Reboot the Change and configure VLANs

After the swap comes again up, you have to to reconfigure the VLANs you want.

Nonetheless if the person sees the identical error after steps 1 and a pair of, then it’s time to exchange the Flash reminiscence on the swap. FLASH reminiscence mo many instances that it has lived out its life and it’s starting to fail.